93
Copyright 2017 SolarCity Corporation. All rights reserved.
Chapter 1 - Welcome
9.1.4 - AC Output
The AC output specifications of the SolarCity H6 inverter are:
• Nominal/Continuous Output Power (L-N / L-L): 3000W/6000W
• Max. Surge Power (L-N / L-L): 3400W/6800W for 10 seconds
• Utility Grid Support: Split-phase, three (3) wire connection
• Operating Voltage Range: 105V to 132V / 211V to 264V (ANSI C84.1)
• Nominal/Continuous Output Current: 25A
• Peak Output Current: 28.3A (surge)
• Nominal Frequency: 60Hz
• Frequency Range (adjustable): 59.3Hz-60.5Hz (44Hz-65Hz)
• Nighttime (standby) Consumption: <6W
• Total Harmonic Distortion: I
THD
, V
THD
<5% (at nominal power)
• Power Factor: >0.995 (0.8ind-0.8cap; at nominal power)
• AC Overcurrent Protection: 35A
• Off-Grid Transition Time: <2 seconds
• Conduit and Wire Size: Two (2) 3/4” conduit; 8-10AWG
9.1.5 - Battery Pack Interface
The battery pack interface specifications of the SolarCity H6 inverter are:
• Operating Battery Pack Voltage Range: 430-550V
• Max. Battery Pack Voltage @ Interface: 570V
• Nominal/Surge Current: 14.3A / 20A
• DC Disconnect: Internal (same as the PV disconnect)
• Internal Fuses (for Battery Pack): Two (2) 25A
• Max. Continual Charge Power: Up to 5000W
• Max. Continual Discharge Power: 5000W
• Surge Power: 7,000W (for 10 seconds)
• Communication Interface to the Inverter: CAN
• Dark Start Functionality: Yes
• Conduit and Wire Size: 1 x 3/4” (plus 1 x 1/2” optional); 8-12AWG HV; 16-24AWG comms