Default Node Poll Interval
Devices are regularly polled to determine status and response time on this
designated interval. By default, this interval is 120 seconds.
Default Volume Poll Interval
Volumes are regularly polled to determine status and response time on this
designated interval. By default, this interval is 120 seconds.
Default Rediscovery Interval
Your entire network is polled on this interval to detect any re-indexed
interfaces. Monitored network devices are also checked for IOS upgrades
permitting EnergyWise support. By default, this interval is 30 minutes.
Note: In SolarWinds products released prior to SolarWinds NPM version 10.1,
the minimum interval allowed is 1 minute. Beginning with SolarWinds NPM
version 10.1, the minimum rediscovery interval is 5 minutes. Polling interval
settings may not be submitted if the default rediscovery interval is not set to at
least 5 minutes.
Lock custom values
This option is enabled by default. Enabling this option automatically saves any
polling customizations made on the Polling Settings view.
Polling Statistics Intervals
The following settings configure default polling intervals for device statistics. To
apply poller settings, click ReApply Polling Statistic Intervals.
Default Node Statistics Poll Interval
Device performance statistics are regularly polled on this interval. By default,
this interval is 10 minutes.
Default Volume Statistics Poll Interval
Volume performance statistics are regularly polled on this interval. By default,
this interval is 15 minutes.