5-3. Camera System Adjustment
5-3-1. Black Set Adjustment
Measuring equipment : waveform monitor(R,G,B)
Measuring point : SDI 1 terminal
Preparation
• Setting for MSU
CLOSE button → ON (lit)
MASTER GAIN → 12
Procedure
1. Set as follows by camera setup menu.
MENU:MAINTENANCE
PAGE:OUTPUT FORMAT
ITEM:CURRENT → 4K59.94P
2. Open following page by camera setup menu.
MENU:SERVICE
PAGE:BLACK SHADING
3. Adjust this using the waveform monitor so that the pedestal level of R,G or B each channel becomes equal within
a range of -6 to +12 dB.
ITEM:BLK SET [R], [G], [B]
4. Store the file.
MENU:SERVICE
PAGE:BLACK SHADING
ITEM:STORE FILE
5. Change item of procedure 1, store the file every following format.
Format
• 4K59.94P (2x)
• HD59.94P (2x)
• HD59.94P (4x)
• HD59.94P (8x)
File store
MENU:SERVICE
PAGE:BLACK SHADING
ITEM:STORE FILE
5-3-2. Sensitivity Adjustment
Measuring equipment : waveform monitor (R,G,B)
Measuring point : SDI 1 terminal
Subject : Grayscale chart
HDC4300
5-10