5-3. Camera System Adjustment
5-3-1. Black Set Adjustment
Measuring equipment : waveform monitor(R,G,B)
Measuring point : SDI 1 terminal
Preparation
Setting for MSU
CLOSE button → ON (lit)
MASTER GAIN → 12
Procedure
1. Set as follows by camera setup menu.
MENUMAINTENANCE
PAGEOUTPUT FORMAT
ITEMCURRENT → 4K59.94P
2. Open following page by camera setup menu.
MENUSERVICE
PAGEBLACK SHADING
3. Adjust this using the waveform monitor so that the pedestal level of R,G or B each channel becomes equal within
a range of -6 to +12 dB.
ITEMBLK SET [R], [G], [B]
4. Store the file.
MENUSERVICE
PAGEBLACK SHADING
ITEMSTORE FILE
5. Change item of procedure 1, store the file every following format.
Format
4K59.94P (2x)
HD59.94P (2x)
HD59.94P (4x)
HD59.94P (8x)
File store
MENUSERVICE
PAGEBLACK SHADING
ITEMSTORE FILE
5-3-2. Sensitivity Adjustment
Measuring equipment : waveform monitor (R,G,B)
Measuring point : SDI 1 terminal
Subject : Grayscale chart
HDC4300
5-10