EasyManuals Logo

Still R70-40T User Manual

Still R70-40T
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #174 background imageLoading...
Page #174 background image
5 Operation
Behaviour in emergencies
Disconnecting the battery
In order to quickly disconnect the battery in the
event of a dangerous situation (e.g. a burning
cable or electrical malfunction), the negative
battery terminal is provided with a quick-dis-
connect battery-terminal clip.
NOTE
The battery is located on the left side, under-
neath the floorplate.
Use the following procedure to quickly discon-
nect the battery:
7071_003-068
1
– Using the handle (1), lift the floorplate.
7071_003-123
– Pull the negative terminal battery-terminal
clip upward.
– Lift the battery-terminal clip off the negative
terminal of the battery and place it to the
side.
164 171673 [EN]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Still R70-40T and is the answer not in the manual?

Still R70-40T Specifications

General IconGeneral
BrandStill
ModelR70-40T
CategoryForklifts
LanguageEnglish