3 Safety
Safety inspections
(see ⇒ Chapter "Definition of terms used for
responsible persons", P. 20) must ensure
that the harmful substances in the exhaust
are checked by a specialist at recurring and
regular intervals, at least every six months,
(see ⇒ Chapter "Definition of terms used for
responsible persons", P. 20).
Type and scope of tests may differ according
to the country. Observe different statutory pro-
visions in the respective operating countries
when using LPG trucks.
Insulation testing
The industrial truck insulation must have a
sufficient insulation resistance. For this rea-
son, an insulation test in accordance with
DIN 57117 and DIN 43539, VDE 0117 and
VDE 0510 must be conducted at least once
every year.
NOTE
Contact your service centre to arrange for an
insulation test.
Testing the insulation resistance of the
electrical system
NOTE
Nominal battery voltage < test voltage < 500 V.
– Ensure that all voltage sources have been
disconnected from the circuit to be tested.
– Measure the insulation resistance with a
suitable gauge.
The insulation resistance can be considered
sufficient if it measures at least 1000
/V for
nominal battery voltage against ground.
28 171673 [EN]