Maintenance 6
Cleaning
CAUTION
Failure to follow these instructions could result in
damaged components.
Steam jet cleaners may be used with max. 50 bar
at 85°C at a distance of at least 20 cm.
Do not directly spray electric motors and other elec-
trical components or their covers.
Do not aim the cleaning jet directly at stickers or
notices.
Plastic parts, particularly on the console, may only
be cleaned with plastics cleaners (display windows
could become cloudy).
7071_003-091
Cleaning the electrical system
CAUTION
Cleaning electrical system parts
with water can damage the electrical
system.
Cleaning electrical system parts with
water is forbidden!
Only use a dry cleaning agent
according to the manufacturer’s
specifications.
Do not remove covers etc.
– Clean and dry electrical system parts with
weakly compressed air and a metal-free
brush.
6327_003-016
Clean load chains
WARNING
Risk of accident!
Load chains are safety elements.
The use of cold/chemical cleaners or fluids that are
corrosive or contain acid or chlorine can damage
the chains and is forbidden!
– Place a collection vessel under the lift mast.
– Use paraffin derivatives such as benzene
for cleaning (take note of the manufacturer’s
safety information.)
– When cleaning with a steam jet, do not use
additives.
171673 [EN] 197