5 Operation
Refuelling
6
7
8
7081_003-005
– Swing the handle of the tensioning device
(6) upwards and remove the hook (8) from
the mounting support.
– Remove the top of the cylinder holder (7).
– Exchange the empty gas cylinder for a full
one.
NOTE
When installing the gas cylinder, make sure
that the connection screw joint of the cylinder
shut-off valve points vertically downwards.
– Secure the gas cylinder in the cylinder
holder properly and check the connections
for leaks.
7081_003-028
1
2
Filling the LPG tank
DANGER
There is a risk of explosion if LPG
escapes!
Smoking, open flames and fire are
forbidden when filling the LPG tank.
– Stop the engine.
– Note safety regulations for
working with LPG ⇒ Chap-
ter "LPG", P. 3-30.
DANGER
Risk of explosion from spark
discharge!
The shut-off valve or locking cap
must not be opened or closed with
the aid of a striking tool.
DANGER
Open flames, red-hot objects etc.
may cause explosions.
– Thaw frozen system components
only with hot water, hot sand bags
or the like.
Follow the instructions given below: