5 Operation
Shut-down
– Lubricate the forklift truck.
– Remove LPG cylinder.
– Check the condition and acid density of
the battery and maintain the battery as
specified by the manufacturer; see ⇒ Chap-
ter "Servicing the battery", P. 6-204. (Fol-
low the instructions provided by the bat-
tery manufacturer.) Only store completely
charged batteries.
– Apply a suitable contact spray to all ex-
posed electrical contacts .
– Preserve the engine as specified by the
manufacturer.
CAUTION
Prevent permanent deformation of the tyres.
Jack up the truck so that all wheels are off the
ground.
CAUTION
We do not recommend using a plastic sheet as this
promotes the formation of condensation.
– Cover the truck with a cotton sheet and protect
against dust.
If the truck is to be shut down for even longer
periods, contact your service centre for addi-
tional recommended measures.
Returning to service after storage
If the truck has been in storage for longer than
six months, it must be carefully checked be-
fore being put back into service.
As in the UVV (accident prevention) inspection
or the annual inspection, this check should
also include all safety items for the truck.
– Clean truck thoroughly; see ⇒ Chap-
ter "Cleaning", P. 196.
– Oil joints and controls.
– Check battery condition and acid density;
recharge if necessary.
– Restore engine to normal condition accord-
ing to regulations of engine manufacturer.
174 171673 [EN]