4-18 Sun Blade 150 Service Manual June 2002
Caution Before you reset to the default parameters, you should review the
OpenBoot PROM settings to ensure that there are no changes that you need to save.
Once the defaults are reset, all other OpenBoot PROM settings are permanently
erased from the NVRAM. If you are unsure if you need your old settings, you may
want to save your OpenBoot PROM settings to a file.
Note The default setting for OpenBoot Diagnostics is max.
2. At the ok prompt, type:
You must always invoke the reset-all parameter to change any OpenBoot PROM
parameters
3. At the ok prompt, type:
Note If you do not need to save any custom changes to OpenBoot PROM, you
could use the set-defaults parameter instead of the reset-all parameter. See
Section 3.9, Resetting Variables to Default Settings on page 3-27.)
ok% setenv auto-boot? true
auto-boot? = true
ok% reset-all