097-72020-01 Revision K – December 2005 TimeSource User’s Guide 109
Chapter 4 TL1 Reference
Commands
Aid Parameter Value Description
COM-a MONMSG=b b = ALW View messages from all ports
b = INH View messages from this port only
KEEPALIVE = b b = 1 to
255
Inactive minutes until the unit sends a
COMPLD message to keep the connection
from being closed
b = 0 No COMPLD message is output
ENDOFTEXT = b b = 1 to 9F Hex code at end of all responses
b = 0 No hex code at end of responses
ECHO = b b = ALW Echoes characters received so they appear
on the user’s screen as typed
b = INH Local echo is disabled
COMPRI = b b = ALW0 TL1 commands and responses, no
autonomous messages sent
b = ALW1 TL1 commands and responses,
autonomous messages
b = ALW2 TL1 commands and responses,
autonomous messages whether logged on
or not
b = INH Closes connection, logs off any user (if
logged on), and keeps port from use.
Releases a telnet session from an Ethernet
port (a port cannot close itself).
AUTOLOGOFF = b b = 1 to
255
Inactive minutes until the unit logs off the
user, keeping the connection open
b = 0 Autologoff is disabled
HWCONTROL = b
a
b = ALW Serial port CTS/RTS flow control is enabled
b = INH Serial port CTS/RTS flow control is not
enabled
SWCONTROL = b
1
b = ALW XON/XOFF flow control is enabled
b = INH XON/XOFF flow control is not enabled