EasyManuals Logo

Symmetricom TimeSource 3100 User Guide

Symmetricom TimeSource 3100
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #135 background imageLoading...
Page #135 background image
097-72020-01 Revision K – December 2005 TimeSource User’s Guide 135
Chapter 4 TL1 Reference
Commands
Retrieve Condition Equipment
This command displays current alarms and events for the specified equipment.
RTRV-COND-EQPT:[<tid>]:<aid>:<ctag>;
Command Example:
RTRV-COND-EQPT::TS3100:<ctag>;
If there are no alarms:
<sid> <date> <time>
M <ctag> COMPLD
/*LINK:<link>,CMD:<command>*/
;
If there is at least one alarm:
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:<ntfcncde>,<condtype>,<srveff>,
<ocrdat>,<ocrtm>,,,\"<conddescr>\""...
/*LINK:<link>,CMD:<command>*/
;
Refer to Chapter 5, Troubleshooting, for a list of all <conddescr> messages, and the
recommended action.
Aid x Value Item Addressed
TS3100 System
SPAN-x x = A E1 span A input
x = E1 span B input
RO-x x = A Remote oscillator A input
x=B Remote oscillator B input
GPS GPS receiver