097-72020-01 Revision K – December 2005 TimeSource User’s Guide 113
Chapter 4 TL1 Reference
Commands
Edit Equipment
This command changes equipment parameters. Additionally, this command can
cause an input to be ensembled. The command format is:
ED-EQPT:[<tid>]:<aid>:<ctag>:::<spec_block>;
The parameters which can be entered in the <spec_block> are listed below. For any
specific <aid> entered in a command, only certain parameters are valid. For each
valid parameter, choose the appropriate value of “a” from the “Value” column. When
entering multiple parameters, separate the parameters with commas.
Aid Value Item Addressed
TS3100 – System-wide configuration
GPS – GPS configuration
RO-a a=A Remote oscillator A input
a=B Remote oscillator B input
SPAN-a a=A E1 span A input
a=B E1 span B input
E1-a a=A E1 A output
a=B E1 B output
OPT-a a=1 to 8 E1 option outputs: 1 through 8
(990-72020-02, 990-72020-06 systems only)
a=1 to 2 ESCIU option ports: 1 or 2
(990-72020-04 systems only)