Chapter 6 Specifications
Additional Analog Outputs (990-72020-02 System Only)
188 TimeSource 3100 User’s Guide 097-72020-01 Revision K – December 2005
Additional Analog Outputs (990-72020-02 System Only)
Connector Type: Wire-wrap pins for 120 Ω balanced terminations
BNC for 75 Ω unbalanced terminations
Connector Label:
Wire-Wrap (8 sets) T
R
S
BNC: OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
OUT 8
Connector Location: Connector panel output module
Impedance: 120 Ω ±5% balanced or
75 Ω ±5% unbalanced
Bit Rate: 2.048 MHz
Frequency Accuracy:1 x 10
-12
GPS Holdover Stability: 1 x 10
-10
per day (0 °C to +50 °C, ±5 °C)
(after one week of 3.2 x 10
-11
per day with a span input
meeting steady-state operation)
ANSI T1.101 network specification 99% probability 1 x 10
-10
per day for 30 days (0 °C to +50 °C, ±5 °C) with an ST2E
remote oscillator input
Format: Square wave
Amplitude: 1.5 V nominal terminated with 120 Ω balanced
1.18 V nominal terminated with 75 Ω unbalanced

Table of Contents

Other manuals for Symmetricom TimeSource 3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeSource 3100 and is the answer not in the manual?

Symmetricom TimeSource 3100 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeSource 3100
CategoryGPS
LanguageEnglish

Related product manuals