097-72020-01 Revision K – December 2005 TimeSource User’s Guide 129
Chapter 4 TL1 Reference
Commands
Retrieve Alarm All
This command displays all current system alarms. The command format is:
RTRV-ALM-ALL:[<tid>]:ALL:<ctag>;
If there are no alarms:
<sid> <date> <time>
M <ctag> COMPLD
/*LINK:<link>,CMD:<command>*/
;
If there is at least one alarm:
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:<ntfcncde>,<condtype>,<srveff>,
<ocrdat>,<ocrtm>,,:\"<conddescr>\""...
/*LINK:<link>,CMD:<command>*/
;
Refer to Chapter 5, Troubleshooting, for a list of all <conddescr> messages, and the
recommended action.