Chapter 3 Installing the TimeSource 3100
Powering Up the Shelf
76 TimeSource 3100 User’s Guide 097-72020-01 Revision K – December 2005
b = allow the input to be ensembled or inhibit the input from being ensembled (y =
ALW causes the input to be monitored and ensembled; y = INH causes the input
to be monitored, but not ensembled)
21.Use the Edit Equipment command to set the frequency of the remote oscillator
inputs.
ED-EQPT::TS3100:<ctag>:::ROFREQ=a;
where:
a = remote oscillator frequency in MHz (a = 5 or 10)
22.If the results of Step 19 indicate the E1 span inputs are set as desired, skip to
Step 25. Use the Enter Equipment command to monitor each available E1 span
input, and to specify whether those inputs are to be ensembled.
ENT-EQPT::SPAN-a:<ctag>:::ENSEMBLER=b;
where:
a = E1 span input (a = A or B)
b = allow the input to be ensembled or inhibit the input from being ensembled
(b = ALW or INH) b = ALW causes the input to be monitored and ensembled;
b = INH causes the input to be monitored, but not ensembled
Set the Output Parameters
23.Use the Edit Equipment command to set the output signal framing format for
each E1 output, and set the mode for each E1 output during an alarm.
ED-EQPT::E1-a:<ctag>:::FRAMING=b,ALMOUT=c;
where:
a = E1 output (a = A or B)
b = framing format (b = CAS, CAS4, CCS, or CCS4, or NONE for analog)
c = E1 output during alarm (c = AIS, SQUELCH, or SSM) (for SSM, framing
format must be CAS4 or CCS4)
Set the Performance Monitoring Parameters
24.If you are not using performance monitoring, skip to Step 25. Use the Initialize
Register command to reset the performance monitoring data to zero for all input
spans.
INIT-REG-EQPT::SPAN-a:<ctag>::ALL;
where:
a = SPAN input (a = A, B, or ALL)
ALL = resets all performance monitoring data

Table of Contents

Other manuals for Symmetricom TimeSource 3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeSource 3100 and is the answer not in the manual?

Symmetricom TimeSource 3100 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeSource 3100
CategoryGPS
LanguageEnglish

Related product manuals