- 135 -
6.6.7.1 Details of Sensor Adjustment Value Display
(1) Sensor A/D value display
H : + 2 0 ° C A : + 2 2 ° C
[ R E F L E C T ]
3.8V
[ T R A N S . ]
2.3V
[ P E ] R 4 . 6 V T 4 . 3 V
[ B A T T E R Y ] 1 6 . 5 V
(2) Supplemental explanations
During a sensor check, status of each sensor is monitored and displayed every 200 msec.
(The display changes in accordance with sensor status.)
When the [FEED] and [PAUSE] keys are simultaneously pressed, the display returns to the
system mode menu.
Ambient thermistor status
(-15 °C to 86 °C)
Thermal head thermistor status
(-15°C to 86 °C)
Reflective sensor status
(0.0 V to 5.0 V)
Transmissive sensor status
(0.0 V to 5.0 V)
Transmissive sensor level without paper
((0.0 V to 5.0 V)
Reflective sensor level without paper
((0.0 V to 5.0 V)
Battery voltage status
B-EP2: 7.2V to 8.4 (9.4)V
B-EP4: 14.0V to 16.8 (17.4)V
* The voltage in parenthesis indicates an upper limit
which does not cause a high voltage error.