6.6.3.2.5 Control Code Setting (CODE)
This setting selects a control code to be used in TPCL mode.
C O D E A U T O
Automatic selection between {.|.} method
and ESC.LF.NUL method
[PAUSE]
C O D E { , | , }
{.|.} method
[PAUSE]
C O D E E S C , L F , N U L
ESC.LF.NUL method
[PAUSE]
Default value: AUTO (Automatic selection)
<Supplemental Explanations>
y When the [FEED] key is pressed, the menu moves in the opposite direction from when the [PAUSE]
key is pressed.
y When the [FEED] and [PAUSE] keys are simultaneously pressed, the display returns to the system
mode menu.
y When the [FEED] key or [PAUSE] key is pressed for 0.5 seconds or more during this parameter
setting, repeat mode is enabled and the key pressed is repeatedly entered.
y The change in the parameter setting becomes effective when the [POWER] key is pressed after
setting, then stored in the backup memory.
y This setting is effective in TPCL and TPCL1 modes.
(1) AUTO
As an interface command control code, [ESC](1BH),[LF](0AH),[NUL](00H) or
{(7BH),|(7CH),}(7DH) is automatically selected. After the power is turned on, the data from the
host is checked for [ESC] and {, and the data sent first is assumed to be a control code.
For example, if [ESC] is sent first, [ESC].[LF].[NUL] is a control code, and if { is sent first, {.|.} is a
control code. The control code is selected for each command.
If the first command ends with [ESC]~ [LF][NUL] and is followed by [ESC], the control code is
[ESC].[LF].[NUL]. If { is sent first, the control code for the next command is {.|.}.
When the control code is {.|.}, the data of 00H to 1FH in { ~ | } is ignored.
However, the data of 00H to 1FH becomes valid while processing the graphic command or
writable character command in hexadecimal mode. When {.|.} is a control code, {.|.} cannot be
used in the data of the Data command or Display command.