- 87 -
(2) Manual Selection (ESC.LF.NUL)
The control code of the command is [ESC](1BH),[LF](0AH),[NUL](00H), and the control code
selection is not performed.
(3) Manual Selection ({.|.})
The control code of the command is {(7BH),|(7CH),}(7DH), and the control code selection is not
performed. Data of 00H to 1FH is ignored and discarded of in this mode. However, data of
00H to 1FH becomes valid while processing the Graphic command or Writable Character
command in hexadecimal mode.
{.|.} cannot be used in the data of the Data command or Display command.
Power ON
Reads received data.
<Is the received data
Assume a control code to
be ESC.LF.NUL.
Command processing
<Is the received data { ?>
Assume a control
code to be {.|.}.
Discards of read
data.
Yes
No
Yes
No