iSTAR eX Capacities
iSTAR eX Installation and Configuration Guide 1–21
Table 1.1 and Table 1.2 provide summaries of connections and capacities.
NOTE
The two outputs have not been evaluated by UL.
Table 1.1: iSTAR eX GCM Capacities
Reader Type Input Connection Output Connection
4 Direct connect
Wiegand Read
Heads
16 Inputs
max = 16 inputs
4 Relay Outputs
4 OC Outputs
max = 8 outputs
NOTE
For UL compliance, the four (4) OC (open collector) outputs cannot be
used when eight (8) RM readers are connected.
Table 1.2: PMB Capacities
Reader Type Input Connection Output Connection
8 RM Readers or
Up to 16 Wyreless
PIMs with up to 16
Wyreless readers.
max = 16 Wyreless
readers
2 Inputs per RM reader
8 I/8 Modules (8 inputs
each)
max = 80 inputs
2 outputs per RM
reader
a
8 R/8 Modules (8
outputs each)
max = 80 outputs
a. With optional ARM-1 modules, unless RM-4E is used.
NOTE
The RM-4, RM-4e, ARM-1, and Wyreless readers have not been evaluated
by UL for use with iSTAR eX.