administration.fm
A31003-S2030-M100-11-76A9, 01/2015
OpenStage SIP V3R3 for OpenScape Voice, Administration Manual
179
Administration
Multiline Appearance/Keyset
Data required
• Rollover ring: Determines if a ring tone will signal an incoming call while a call is active.
Value range: "Standard ring", "No ring", "Alert beep", "Alert ring"
Default: "Alert beep"
• LED on registration: Determines if line LEDs will signal SIP registration.
Value range: "Yes", "No"
Default: "Yes"
• Originating line preference: Selects the line to be used for outgoing calls.
Value range: "Idle line", "Primary", "Last", "None"
Default: "Idle line"
• Terminating line preference: Determines which line with an incoming call shall be select-
ed for answering.
Value range: "Ringing line", "Incoming", "Incoming PLP", "Ringing PLP", "None"
Default: "Idle line"
• Line action mode: Determines the consequence for an established connection when the
line key is pressed.
Value range: "Hold", "Release"
Default: "Hold"
• Show focus: Determines whether the line key LED blinks or is steady when it is in use.
Value range: "Yes", "No"
Default: "Yes"
• Reservation timer: Sets the period in seconds after which a line reservation is cancelled.
If set to 0, the reservation timer is deactivated.
Default: 60
• Forward indication: Activates or deactivates the indication of station forwarding.
Value range: "Yes", "No"
Default: "No"
• Preselect mode: Determines whether an incoming call is accepted by a single press on
the corresponding line key or a double press is needed.
Value range: "Single button", "Preselection"
Default: "Single button"
• Preselect timer: Sets the timeout in seconds for accepting an incoming call.
• Bridging enabled (see Admin > Features > Configuration) : When set to "Yes", the user
is allowed to join a call on a shared line. For this purpose, a server based conference is
established.

Table of Contents

Other manuals for Unify OpenStage 15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unify OpenStage 15 and is the answer not in the manual?

Unify OpenStage 15 Specifications

General IconGeneral
DisplayYes
Display Lines2
KeypadYes
SpeakerphoneYes
Volume ControlYes
Wall MountableYes
Headset PortYes
Power over Ethernet (PoE)Yes
Ethernet Port1
ProtocolsSIP
Dimensions200 x 200 x 90 mm
Weight0.8 kg

Related product manuals