EasyManuals Logo

Unify OpenStage 15 Administration Manual

Unify OpenStage 15
412 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #377 background imageLoading...
Page #377 background image
beispiele.fm
A31003-S2030-M100-11-76A9, 01/2015
OpenStage SIP V3R3 for OpenScape Voice, Administration Manual
377
Examples and HowTos
Canonical Dialing
5 Examples and HowTos
5.1 Canonical Dialing
5.1.1 Canonical Dialing Settings
The following example shows settings suitable for the conversion of given dial strings to canon-
ical format. The example phone is located in Nottingham, UK.
Parameter Example value Explanation
Local country code 44 International country code for the UK.
National prefix digit 0 Used in front of national codes when dialled
without international prefix.
Local national code 115 Area code within the UK (here: Nottingham).
Minimum local number
length
7 Minimum number of digits in a local PSTN
number (e. g. 3335333 = 7 digits).
Local enterprise node 780 Prefix to access Nottingham numbers from
within the Siemens network.
PSTN access code 9 Prefix to make an international call in the UK.
Operator codes 0,7800 Set of numbers to access the local operators.
(No blank after comma, or else the subsequent
entry is ignored.)
Emergency numbers 999,555 Set of numbers to access emergency ser-
vices. (No blank after comma, or else the sub-
sequent entry is ignored.)
Initial extension digits 2,3,4,5,6,8 1
st
digits of numbers that are used for extensi-
on numbers on the local node. (No blank after
comma, or else the subsequent entry is igno-
red.)

Table of Contents

Other manuals for Unify OpenStage 15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unify OpenStage 15 and is the answer not in the manual?

Unify OpenStage 15 Specifications

General IconGeneral
BrandUnify
ModelOpenStage 15
CategoryTelephone
LanguageEnglish

Related product manuals