Diagnostics
3.26.14 Remote Tracing – Syslog
All trace messages created by the components of the phone software can be sent to a remote
server using the syslog protocol. This is helpful especially for long-term observations with a
greater number of phones.
To enable remote tracing, Remote trace status must be set to "Enabled". Furthermore, the IP
address of the server receiving the syslog messages must be entered in Remote ip, and the
corresponding server port must be given in Remote port.
With version V2, the User notification parameter controls whether the user is notified about
the remote tracing or not. If user notification is enabled, a blinking symbol ( on OpenStage
60/80; on OpenStage 15/20/40) will inform the user when remote tracing is active, that is,
when Remote trace status is set to "Enabled".
Administration via Local Phone
Administration via WBM
|
--- Admin
|
--- Maintenance
|
--- Remote trace
|--- Remote trace status
|--- User notification
|--- Remote ip
|
--- Remote port
Remote trace
Remote Trace Status
Use Notification
Remote Server
Enabled
Remote Server Port
514
Submit
Reset
Disabled

Table of Contents

Other manuals for Unify OpenStage 15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unify OpenStage 15 and is the answer not in the manual?

Unify OpenStage 15 Specifications

General IconGeneral
BrandUnify
ModelOpenStage 15
CategoryTelephone
LanguageEnglish

Related product manuals