EasyManua.ls Logo

Vaisala AWS310-SITE - WMT700 Cable Wiring

Vaisala AWS310-SITE
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. In Log File, set the following:
Storage directory
Select Browse and specify the folder for storing the downloaded log files.
Convert to CSV
Select to convert the downloaded log files to CSV format. When selected, the
following options become available:
Merge log files of the same group: Merges log files from dierent dates
belonging to the same log group.
Delete local files after conversion: Deletes the downloaded binary log files
after they have been converted to CSV format.
Separate date and time columns: Display the date and time string in the log
file in separate columns.
Delete remote file after download
Select to delete the log file from the QML data logger after it has been
downloaded (to conserve storage space).
Existing log file
Select the action in case there is an existing log file with the same name. The
following options are available:
Overwrite: Overwrites the existing log file.
Skip: Skips the saving of the new file.
Stop downloading: Stops downloading the selected log files.
4. To save the changes, select Save.
AWS Client waits in the idle mode until polling is triggered. When polling, the application
automatically opens a service connection to the automatic weather station and downloads
the log
files as defined by the user.
Auto download is not performed if, at the time of polling, AWS Client is occupied with
something else (for example, calibration) that requires commands to be sent to the
logger.
When the log files are downloaded, the connection is closed and the application continues
to wait in the idle mode until a new prescheduled polling event is triggered.
Chapter 4 – AWS Client Usage