Figure 6 QML Data Logger without Cover
1 Pressure sensor connector
2 Communication module slots MOD1 and MOD2
3 SPI connector for QMD202 local display
4 Status LED (green)
5 Lithium battery for real-time clock (3 V 35 mAh CR1220)
6 Reset button
7 CompactFlash (CF) card slot
1. Take a backup of the station parameters.
If you cannot access the QML data logger, try to find an old backup file.
2. Turn o DC power from the battery fuse switch.
3. Turn o power from the weather station main switch.
4. Unplug the connectors from the QML data logger.
To have more slack in the wiring, you may need to cut the cable ties holding the wires.
To avoid damaging the wiring, do this from the bottom side of the installation plate.