EasyManua.ls Logo

Vaisala AWS310-SITE - Air Temperature and Relative Humidity Message for WID Displays; Atmospheric Pressure Message for WID Displays

Vaisala AWS310-SITE
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.11.17 Air Temperature and Relative Humidity Message for WID
Displays
The system forwards this message to WID displays as it is received from the sensor. The
system does not send this message by default, but you can activate it with parameter
TU_WID. For more information on the message, see Vaisala HUMICAP
â
Humidity and
Temperature Probe HMP155 User's Guide.
Air Temperature and Relative Humidity Message for WID Displays
Characteristics
Property Value
Default send interval 15 s
Polling command
TUWIDREP
Example of Air Temperature and Relative Humidity Message for WID Displays
FORM #001 "HMP155," ADDR #002 3.2 RH "," T "," U2 "," TD "," TDF "," TW "," X
"," STAT "," ERR #003 CS4 #r#n
4.11.18
 Atmospheric Pressure Message for WID Displays
The system forwards this message to WID displays as it is received from the sensor. The
system does not send this message by default, but you can activate it with parameter
PA_WID. For more information on the message, see Vaisala BAROCAP
â
Digital Barometer
PTB330 User's Guide.
Atmospheric Pressure Message for WID Displays Characteristics
Property
Value
Default send interval 60 s
Polling command
PAWIDREP
Example of Atmospheric Pressure Message for WID Displays
FORM #001 "PTB" ADDR #002 ERR " " 4.2 P " " P3H " " A3H " " P1 " " P2 " " P3
#003 CS4 #rn
4.11.19
 TABLE Report
The TABLE report gives data about the weather station and its sensors. This data is useful
for onsite maintenance and can help find problems within the system.
AWS310-SITE Configuration and Maintenance Manual M211828EN-C
76