Soil Temperature 1 Message Characteristics
Property Value
Default send interval 60 s
Polling command
TS1REP
If there is no soil temperature 1 data available, the message is substituted with the following:
TS1 data missing<CR><LF>
Example of Soil Temperature 1 Message
<SOH>TS1<STX> 38.8 DA69<ETX><CR><LF><EOT>
4.11.12
 Soil Temperature 2 Message for AviMet
Soil Temperature 2 Message Format
<SOH>TS2<STX> xxx.x <CRC16 %04d><ETX><CR><LF><EOT>
Name
Description
<SOH>TS2<STX>
Message header
xxx.x
Soil temperature (°C), 1minute average
<CRC16 %04d>
Message checksum:
Checksum span = Includes header, until checksum
<ETX><CR><LF><EOT>
Message trailer
Soil Temperature 2 Message Characteristics
Property
Value
Default send interval 60 s
Polling command
TS2REP
If there is no soil temperature 2 data available, the message is substituted with the following:
TS2 data missing<CR><LF>