4.9.8 QML Logger Connections
The following table shows a list of QML logger connections, measurement components, and
raw measurements.
Table 9 QML Logger Connections
Function Component
Name
Device Interval[s] QML Logger
Connector
Parameters,
Measurement
Type
Service line COM0 Serial cable COM0 RS-232;
9600,8,N,1
Message parser
for WA15 and
WMT703
WAC155
WMT700
WAC155
WMT700
1 COM1 RS-485;
9600,8,N,1
Message parser
for HMP155
HMP155 HMP155 10 MOD 1/1
DSI486_0_0
RS-485;
9600,8,N,1
Message parser
for PTB330
PTB330 PTB330 60 MOD 2/1
DSI486_ 1_0
RS-485;
9600,8,N,1
Message parser
for PWD22
FD12P PWD22 15 MOD 1/1
DSI486_0_0
RS-485;
9600,8,N,1
Message parser
for FS11(P)
FD12P FS11 or FS11P 15 MOD 1/1
DSI486_0_0
RS-485;
9600,8,N,1
Message parser
for CL31
CL31 CL31 15 MOD 1/1
DSI486_0_0
RS-485;
9600,8,N,1
Rain gauge
measurement
Rain_PLUVIO
Pluvio
2
L
60 MOD 1/3
DSI486SDI_0
SDI-12
RG13 tipping
bucket
measurement
Precipitation RG13 60 CHB E pin; pulse
counter
QMD202 local
display
QMD_1 QMD201_1 10 EXT_SPI
Soil
temperature
measurement
TempSoil_1 QMT110_1 10 CH1 Pt100
Soil
temperature
measurement
TempSoil_2 QMT110_2 10 CH2 Pt100
Air temperature
measurement
TAMeasHMP155 HMP155_PT100 10 CH7 Pt100
AWS310-SITE Configuration and Maintenance Manual M211828EN-C