System Configuration
DME Admin Guide 81
Field Description
Max. Number of RTP C
onnections
Range: 0–1000. Select this value based on number of expected
connections. When selecting the number of connections, the total
expected bandwidth of the streams should not exceed
recommendations. The recommendations shown here for each
model are for total throughput (input and output) in megabits per
second:
DME Model BPS 7530 - Do not exceed 100 Mbps.
- Hardware Part # 8000-0222-0x00
- Software Part # 7500-0250-0x00
DME Model XPS 7550 - Do not exceed 500 Mbps.
- Hardware Part # 8000-0223-0x00
- Software Part # 7500-0251-0x00
DME Model HPS 7570 - Do not exceed 3000 Mbps.
- Hardware Part # 8000-0224-0x00
- Software Part # 750-0252-0x00
Defaults (7530/7550/7570): 100/100/100
Max. Number of Multi
Protocol Connections
The maximum number of allowed connections. This will vary by
DME model.
DME Model 7530 - May not exceed 100.
DME Model 7550 - May not exceed 1000.
DME Model 7570 - May not exceed 2200.
Defaults (7530/7550/7570): 100/1000/2200
RTP Server Max.
Throughput
Set maximum allowed throughput in mbit/sec or kbits/sec. See
recommendations above.
Defaults (7530/7550/7570): 100/100/100