111
CHAPTER 5 - START-UP
Type of control
P202 = VVW
Motor Rated Volt
P
4
0
0
=
460 V
Motor Rated Volt
P
4
0
0
=
460 V
Motor Rated Cur.
P
4
01
=
7
.
9
A
Motor Rated Cur.
P
4
01
=
7
.
9
A
Motor Rated Cur.
P
4
01
=
7
.
9
A
Motor Rated Cur.
P
4
01
=
7
.
9
A
ACTION
LED DISPLAY
DESCRIPTION
LCD DISPLAY
Use the and keys to
select the type of control (VVW)
Press the key to save the
selected option and start the tuning
routine after changing to VVW
ControlMode
Press the key and use the
and keys to set the
correct motor rated voltage value
Press the key to save the
programmed value and exit the
programming mode
Press the key to go to the
next parameter
Press the key to enter the
programming mode
Use the and keys to
set the correct motor rated current
value
Press the key to save the
programmed value and exit the
programming mode
Selected Type of Control:
5 = VVW
Motor Rated Voltage Range:
0 to 690 V
Programmed Motor Rated Voltage:
460 V
Exit the programming mode
Motor Rated Current Range:
(0.0 to 1.30) x P295
(1)
Enter the programmingmode
Programmed Motor Rated Current:
7.9 A
Exit the programming mode
Motor Rated Volt
P
4
0
0
=
3
8
0
V