131
4-6-8 Logic converse [CML, DCML]
1) Summary
Logic converse the data
Converse [CML,DCML]
16 bits
CML
32 bits
DCML
Execution
condition
Normally ON/OFF,
rising/falling edge
Suitable
Models
XD, XL
Hardware
requirement
-
Software
requirement
-
2)Operands
Operands
Function
Data Type
S
Source data address
16 bits/32 bits, BIN
D
Result address
16 bits/32 bits, BIN
3)Suitable soft components
Operan
ds
Word soft elements
Bit soft elements
System
Consta
nt
Modul
e
System
D
F
D
T
D
C
D
D
X
D
Y
D
M
D
S
K/H
I
D
Q
D
X
Y
M
S
T
C
Dn.
m
S
D
*Notes: D includes D, HD; TD includes TD, HTD; CD includes CD, HCD, HSCD, HSD;
DM includes DM, DHM; DS includes DS, DHS. M includes M,HM,SMS includes S,HS
T includes T,HTC includes C, HC.
CML D0 DY0
D·
M0
0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
D0
Y17 Y7 Y6 Y5 Y4
Sign
bit
0=positive
1=negative)
Each data bit in the source device is reversed (1→0, 0→1) and sent to the destination device.
If use constant K in the source device, it can be auto convert to be binary.
This instruction is fit for PLC logical converse output.
<Read the converse input>
Description
tudonghoatoancau.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje XDH Series and is the answer not in the manual?

Xinje XDH Series Specifications

General IconGeneral
BrandXinje
ModelXDH Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals