EasyManuals Logo

Xinje XDH Series User Manual

Xinje XDH Series
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #181 background imageLoading...
Page #181 background image
180
COS D50 D60
X0
This instruction performs the mathematical COS operation on the floating point value in S
(angle RAD). The result is stored in D.
D51 D50
D61 D60
Note: Before the instruction is executed, the data in parameter S must be floating number;
otherwise, the execution result will be wrong.
4-9-10 TAN [TAN]
1) Summary
TAN [TAN]
16 bits
-
32 bits
TAN
Execution
condition
Normally ON/OFF,
rising/falling edge
Suitable
Models
XD, XL
Hardware
requirement
-
Software
requirement
-
2) Operands
Operands
Function
Data Type
S
Soft element address need to do tan
32bit,BIN
D
Result address
32bit,BIN
3) Suitable soft components
Operands
Word soft elements
Bit soft elements
System
Constant
Module
System
D
F
D
T
D
C
D
D
X
D
Y
D
M
D
S
K/H
I
D
Q
D
X
Y
M
S
T
C
Dn.
m
S
D
*Notes: D includes D, HD; TD includes TD, HTD; CD includes CD, HCD, HSCD, HSD; DM
includes DM, DHM; DS includes DS, DHS. M includes M, HM, SM; S includes S, HS; T
includes T, HT; C includes C, HC.
Description
(D51,D50)RAD (D61,D60)COS
Binary Floating Binary Floating
RAD value (angle×π/180)
Assign the binary floating value
COS value
Binary Floating
tudonghoatoancau.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje XDH Series and is the answer not in the manual?

Xinje XDH Series Specifications

General IconGeneral
BrandXinje
ModelXDH Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals