<32 bits operation>
ESUB D10 D20 D50
S1· S
X0
<64 bits operation>
The binary floating value S1 subtract S2, the result is stored in the target address.
If a constant K or H used as source data, the value is converted to floating point before the
subtraction operation.
<32 bits operation>
ESUB D100K1234 D110
X1
<64 bits operation>
The source data and result address can be the same. Please note that when X0 is ON, the
instruction will be executed in every scanning period.
Note: the operand value must be floating numbers, otherwise the result will be error.
Description
(D11,D10) (D21,D20) (D51,D50)
Binary Floating Binary Floating Binary Floating
(K1234)
(D101, D100) (D111, D110)
Binary converts to Floating Binary Floating Binary Floating
(D13, D12,D11, D10)(D23,D22,D21,D20) (D53, D52,D51, D50)
Binary Floating Binary Floating Binary Floating
(D13, D12,D11, D10)(D23,D22,D21,D20) (D53, D52,D51, D50)
Binary converts to Floating Binary Floating Binary
Floating