Parameter Details
12
12.11 o: Keypad-Related Settings
YASKAWA SIEPC71061737D GA800 Drive Technical Reference 1053
First Row: Drive Information
This example shows the data text strings and data generated for the first row of log data.
Example of generated data: 00,0012,160107111230,GA800,VSAA09010,2,62,1000,000001
No. Item
Number of
Charac
ters
Example Description
1 Attribute 2 00 [00] shows that the record is a drive information record.
2 File number 4 0012 Generates the [xxx] part (a 3-digit decimal number) of the [GLOG0xxx.csv] filename of the log data in
hexadecimal format.
Example filename of [GLOG0018.csv]: 018 (Dec.) = 0012 (Hex.)
3 Time stamp
*1
12 160107111230 Data log data was retrieved (YYMMDDHHMMSS)
Date: 20YY/MM/DD
Time in 24-hour format: HH:MM:SS
Example data of [160107111230]: 11:12:30 on January 7, 2016
4 Model 5 GA800 Drive model information
5 Software number 9 VSAA09010 Drive software number
6 Control Method Selection 1 2 Setting value (Hex.) of A1-02 [Control Method Selection]
7 Drive capacity 2 62 Setting value (Hex.) of o2-04 [Drive Model (KVA) Selection]
8 Sampling time 5
(Maximum)
1000 Setting value (Dec.) of o5-02 [Log Sampling Interval]
Unit: ms
9 Row number 6 000001 Row number (Hex.) in the data log file
*1 If you do not set the time in the keypad, the text string of [000000000000] is generated to show the time.
Second Row: Log Data Information
This example shows the data text strings and data generated for the second row of log data.
Example of generated data:
01,0012,160107111230,0101,0201,0102,0201,0103,0206,0107,0005,0108,0209,0000,0000,0000,0000,0000,0
000,0000,0000,0000,0000,0000,0000,0000,0000,000002
No. Item
Number of
Characters
Description
1 Attribute 2 [01] shows that the record is a log data information record.
2 File number 4 Generates the [xxx] part (a 3-digit decimal number) of the [GLOG0xxx.csv] filename of the log data in hexadecimal
format.
3 Time stamp 12 Data log data was retrieved (YYMMDDHHMMSS)
4 Monitor Number 1
*1
4 Monitor number selected by o5-03 [Log Monitor Data 1]
Example: 0101 (Dec.) for U1-01
5 Monitor Unit 1
*2
4 Unit code and number of decimal places used for the monitor selected with o5-03
Example when U1-01 = 30.00 Hz:
Number of decimal places = 2, Hz unit code = 01, monitor unit 1 = 0201 (Hex.)
6 Monitor number 2 4 Monitor number (Dec.) set to o5-04 [Log Monitor Data10]
7 Monitor Unit 2 4 Unit code and number of decimal places used for the monitor selected with o5-04
: : : :
22 Monitor number 10 4 Monitor number (Dec.) set to o5-12 [Log Monitor Data10]
23 Monitor Unit 10 4 Unit code and number of decimal places used for the monitor selected with o5-12
24 - 27 Reserved 4 -
28 Row number 6 Row number (Hex.) in the data log file
*1 If there is no data log monitor selected, the text string of [0000] is generated.
*2 Refer to Table 12.78 for information about unit codes.