3.6 Main Circuit Wiring..............................................................................................................39
Main Circuit Terminal Functions
........................................................................................................ 39
Wire Gauges and Tightening Torque ................................................................................................ 39
Main Circuit Terminal Power Supply and Motor Wiring..................................................................... 41
3.7 Control Circuit Wiring .........................................................................................................43
Control Circuit Terminal Block Functions .......................................................................................... 43
Terminal Configuration ...................................................................................................................... 44
Wiring Procedure............................................................................................................................... 45
3.8 I/O Connections...................................................................................................................47
Sinking/Sourcing Mode Switch.......................................................................................................... 47
3.9 Main Frequency Reference.................................................................................................49
DIP Switch S1 Analog Input Signal Selection ................................................................................... 49
3.10 Braking Resistor..................................................................................................................50
Installation ......................................................................................................................................... 50
3.11 Interlocking with Connected Machinery ...........................................................................52
Drive Ready Signal............................................................................................................................ 52
3.12 Wiring Checklist ..................................................................................................................53
4. START-UP PROGRAMMING & OPERATION....................................................... 55
4.1 Section Safety......................................................................................................................56
4.2 Using the Digital LED Operator..........................................................................................58
Keys, Displays, and LEDs ................................................................................................................. 58
Digital Text Display............................................................................................................................ 59
LED Screen Displays ........................................................................................................................ 59
LO/RE LED and RUN LED Indications.............................................................................................. 60
Menu Structure for Digital LED Operator .......................................................................................... 61
4.3 The Drive and Programming Modes..................................................................................62
Navigating the Drive and Programming Modes................................................................................. 62
Changing Parameter Settings or Values ........................................................................................... 65
Verifying Parameter Changes: Verify Menu ...................................................................................... 66
Switching Between LOCAL and REMOTE........................................................................................ 66
Parameters Available in the Setup Group ......................................................................................... 67
4.4 Start-up Flowchart...............................................................................................................68
Flowchart: Basic Start-up .................................................................................................................. 68
4.5 Powering Up the Drive ........................................................................................................69
Powering Up the Drive and Operation Status Display....................................................................... 69
V/f Pattern Setting ............................................................................................................................. 69
4.6 No-Load Operation Test Run..............................................................................................70
No-Load Operation Test Run ............................................................................................................ 70
4.7 Test Run with Load Connected..........................................................................................71
Test Run with the Load Connected ................................................................................................... 71
4.8 Verifying and Backing Up Parameter Settings .................................................................72
Parameter Access Level: A1-01........................................................................................................ 72
Password Settings: A1-04, A1-05 ..................................................................................................... 72
Copy Function (Optional) .................................................................................................................. 72
4.9 Test Run Checklist ..............................................................................................................73
5. PARAMETER DETAILS ......................................................................................... 75
Table of Contents
4
YASKAWA ELECTRIC SIEP C710606 31B YASKAWA AC Drive – J1000 Technical Manual
http://nicontrols.com

Table of Contents

Other manuals for YASKAWA J1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA J1000 and is the answer not in the manual?

YASKAWA J1000 Specifications

General IconGeneral
SeriesJ1000
Voltage Class200V, 400V
Frequency50/60 Hz
Enclosure RatingIP20
Enclosure TypeOpen type
Voltage200-240V, 380-480V
Control MethodV/f control
Overload Capacity150% for 60 seconds
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault, Short Circuit
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Humidity5-95% (non-condensing)
EnclosureIP20
Input Voltage200-240V, 380-480V