Register No. Contents
00D0H
CPF Contents 1
bit 0, 1 Reserved
bit 2 A/D Conversion Error (CPF02)
bit 3 to 5 Reserved
bit 6 EEPROM data fault (CPF06)
bit 7 Reserved
bit 8 EEPROM Serial Communications Fault (CPF08)
bit 9 to A Reserved
bit B RAM Fault (CPF11)
bit C FLASH Memory Fault (CPF12)
bit D Reserved
bit E Control Circuit Fault (CPF14)
bit F Reserved
00D1H
CPF Contents 2
bit 0 Reserved
bit 1 Timing Fault (CPF17)
bit 2 Control Circuit Fault (CPF18)
bit 3 to 5 Reserved
bit 6 A/D Conversion Fault (CPF22)
bit 7 PWM Feedback Fault (CPF23)
bit 8 Drive capacity signal fault (CPF24)
bit 9 to F Reserved
00D2H to 00FBH Reserved
<1> Units are determined by parameter H5-13.
<2>
The communication error log is stored until the fault is reset.
u
Broadcast Messages
Data can be written from the master to all slave devices at the same time.
The slave address in a broadcast command message must be set to 00H. All slaves will receive the message, but will not
respond.
Register No. Contents
0001H
Digital Input Command
bit 0 Forward Run (0: Stop 1: Run)
bit 1 Direction Command (0: Forward, 1: Reverse)
bit 2, 3 Reserved
bit 4 External Fault
bit 5 Fault Reset
bit 6 to B Reserved
bit C Multi-Function Digital Input S5 (enabled when bit C of register 000FH is ON)
bit D to F Reserved
0002H Frequency Reference 30000/100%
C.10 MEMOBUS/Modbus Data Table
228
YASKAWA ELECTRIC SIEP C710606 31B YASKAWA AC Drive – J1000 Technical Manual