6.22 Online Vibration Monitor (Fn207)
6-39
6
Utility Functions (Fn)
(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while exe-
cuting this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter Name
Mid-execution
changes
Automatic
changes
Pn401 Torque Reference Filter Time Constant No Yes
Pn408 Torque Related Function Switch Yes Yes
Pn409 1st Notch Filter Frequency No Yes
Pn40A 1st Notch Filter Q Value No No
Pn40C 2nd Notch Filter Frequency No No
Pn40D 2nd Notch Filter Q Value No No