9.2 Warning Displays
9-27
A.971:
Undervoltage
The AC power supply
voltage dropped to:
140 V or less for 200-
VAC SERVOPACKs.
280 V or less for 400-
VAC SERVOPACKs.
Measure the power supply voltage.
Set the power supply voltage within
the specified range.
The power supply volt-
age dropped during
operation.
Measure the power supply voltage. Increase the power supply capacity.
Occurrence of instanta-
neous power interrup-
tion.
Measure the power supply voltage.
When the instantaneous power cut
hold time (Pn509) is set, decrease the
setting.
A fault occurred in the
SERVOPACK or con-
verter.
The SERVOPACK or converter may
be faulty. Replace the SERVOPACK
or converter.
A.9A0:
Overtravel
(Overtravel status
is detected.)
When the servomotor
power is ON, over-
travel status is detected.
Check the input signal monitor
(Un005) to check the status of the
overtravel signals.
Refer to 9.3 Troubleshooting Malfunc-
tion Based on Operation and Condi-
tions of the Servomotor. Even if
overtravel signals were not shown by
the input signal monitor (Un005),
momentary overtravel may have been
detected. Take the following precau-
tions.
Do not specify movements that
would cause overtravel from the
host controller.
Check the wiring of the overtravel
signals.
Take countermeasures for noise.
(cont’d)
Warning Num-
ber: Warning
Name (Warning
Description)
Cause Investigative Actions Corrective Actions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA SGDV series and is the answer not in the manual?

YASKAWA SGDV series Specifications

General IconGeneral
SeriesSGDV
CommunicationMECHATROLINK-II, MECHATROLINK-III, EtherCAT
Control ModesPosition, Speed, Torque
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Encoder error
Ambient Temperature0°C to 55°C
Cooling MethodNatural cooling or forced air cooling
Voltage200V, 400V
WeightVaries depending on model (e.g., 0.6 kg to 10 kg)

Related product manuals