10 Appendix
10.1.2 Parameters
10-6
Pn008
2 Application Function Select Switch 8 0000 to 7121 4000 After restart Setup
Pn009
2 Application Function Select Switch 9 0000 to 0111 0010 After restart Tuning
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Reference
Section
Lowered Battery Voltage Alarm/Warning Selection
Reference
Section
0 Outputs alarm (A.830) for lowered battery voltage.
4.5.3
1 Outputs warning (A.930) for lowered battery voltage.
Function Selection for Undervoltage
Reference
Section
0 Does not detect undervoltage.
4.2.10
1 Detects warning and limits torque by host controller.
2 Detects warning and limits torque by Pn424 and Pn425. (Only in the SERVOPACK)
Warning Detection Selection
Reference
Section
0 Detects warning.
9.2.1
1 Does not detect warning (except for A.971).
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.

Reserved (Do not change.)
Current Control Method Selection
Reference
Section
0 Current control method 1
5.8.3
1 Current control method 2
Speed Detection Method Selection
Reference
Section
0 Speed detection 1
5.8.5
1 Speed detection 2
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.


Table of Contents