188
Settings->Power Saving->Office Hour Idle TimeOut
Phone User Interface:
None
features.power_saving.off_hour.idle_timeout
Integer
from 1 to 10
10
Description:
Configures the time (in minutes) to wait in the idle state before the IP phone enters
power-saving mode during the non-office hours.
Example:
features.power_saving.off_hour.idle_timeout = 5
The IP phone will enter power-saving mode when it has been inactivated for 5 minutes
during the non-office hours.
Note: It is not applicable to SIP-T19(P) E2 IP phones.
Web User Interface:
Settings->Power Saving->Off Hour Idle TimeOut
Phone User Interface:
None
features.power_saving.user_input_ext.idle_timeout
Integer
from 1 to 30
10
Description:
Configures the minimum time (in minutes) to wait in the idle state - after using the phone -
before the IP phone enters power-saving mode.
Example:
features.power_saving.user_input_ext.idle_timeout = 5
Note: It is not applicable to SIP-T19(P) E2 IP phones.
Web User Interface:
Settings->Power Saving->User Input Extension Idle TimeOut
Phone User Interface:
None
features.power_saving.office_hour.monday
features.power_saving.office_hour.tuesday
features.power_saving.office_hour.wednesday
features.power_saving.office_hour.thursday
features.power_saving.office_hour.friday
features.power_saving.office_hour.saturday
features.power_saving.office_hour.sunday
Integer
from 0 to
23, Integer
from 0 to 23
7,19
7,19
7,19
7,19
7,19
7,7
7,7

Table of Contents