4-20
IM AQ7280-01EN
Screen Display Item: List
1.
From the top menu, select OTDR.
2.
Press the Event Analysis soft key and then the Display soft key to select List. The following
screen appears.
Measurement conditions
For details on the measurement
conditions, see section 2.1.
Analysis values
List display
List Edit
See page 4-22.
Event Note Edit
See page 4-26.
Analysis values
Total RL
The integrated value of the return losses of each event.
Total Loss
Displayed in the following manner depending on the total loss calculation method.
Cumulate loss:
The integrated value of the splice losses at each event from the measurement
reference point (S) is displayed.
Loss between S and E:
The loss between the measurement reference point (S) and the end of fiber (E) is
displayed.