Code Message Chapter or Section
692 Cannot execute for the media itself.
693 Cannot store at Network Drive. 16.3
694 Trigger Event is Off. 7.2
695 File version is new. Update firmware.
696 The file may be damaged or an unsuccessful file close could have occured.
697 Abnormal data file. Unsuccessful finish of file save is detected.
705 Can not operate while accessing medium.
Wait until access has completed.
706 Can not operate during hard copy.
Wait until output has completed.
711 File operation not allowed during hard copy.
Wait until the hard copy completes.
713 Cannot execute for All or Custom display mode.
720 Over Run had occured.
721 Can not set or execute because store is processing. Try Again.
722 No target Element for integration execution. 8.1
723 Can not set or execute when Integ Independent Control is on. 8.1
724 Can not set or execute because recording is processing. Try again.
725 File creation stopped. File size exceeded 2G bytes.
750, 751 Unable to connect to the server.
Check the network settings and configuration.
Chapter 20
752 This ftp function in not supported.
753 FTP Error: Client Handle
Confirm the network settings and connection.
Chapter 20
758 Failed to acquire time from SNTP server.
Confirm the network settings and connection.
20.5
759 Failed to initialize network.
Confirm the network settings.
Chapter 20
800 Illegal date-time.
Set the correct date and time.
3.5*
801 Illegal file name.
The file name contains characters which are not allowed or the file name is not a valid
MS-DOS file name. Enter another file name.
17.2
802 Cannot be set or executed in the Normal measurement mode.
Usable measurement mode are as follows.
811 Cannot be set to this display mode.
Harmonics option is necessary.
812 Cannot be set or executed while storing data.
813 Cannot be set while integration is running.
Reset Integration.
8.3
814 Cannot be set or executed when NULL is on.
Please turn NULL off.
21.9
815 Cannot be set or executed when the Data Update Interval is Auto. 1.15
823 Cannot change during CAL.
Wait until CAL is completed.
21.8
827 Illegal math expression.
Input a correct computing equation.
8.1
831 Processing now.
Retry setting or execution again.
841 Attempted to start integration after integration time has reached its preset value. 8.3
842 Attempted to start integration while integration is in progress. 8.3
843 Measurement stopped due to overflow during integration or due to a power failure. 8.3
844 Attempted to stop integration even though integration was not in progress. 8.3
845 Attempted to reset integration even though integration was in progress or integration
mode was not selected.
8.3
846 Attempted to start integration while measurement of peak overflow was in progress.
847 Attempted to start integration in continuous integration mode when integration preset
time was set to “0”.
8.2
848 Attempted made to start integration in real time counting integration mode when the
end time had already passed.
8.2
849 Attempted made to start storing in real time counting storing mode when the end time
had already passed.
16.1
* Getting started guide, IM WT1801E-03EN
Appendix 1 Messages and Corrective Actions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA WT1801E and is the answer not in the manual?

YOKOGAWA WT1801E Specifications

General IconGeneral
BrandYOKOGAWA
ModelWT1801E
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals