Free space, IP55 (UL Type 12)Frame
size
Vertical mounting side by sideVertical mounting stand alone
Between
Below
1)
AboveBesideBelowAbove
inmminmminmminmminmminmm
007.872007.872005.911504.571165.39137R1
007.872007.872005.911504.571165.39137R2
007.872007.872005.911502.09537.87200R3
007.872007.872005.911507.872002.0953R4
007.872007.872005.911507.872003.94100R5
0011.83007.872005.9115011.83006.10155R6
0011.83007.872005.9115011.83006.10155R7
0011.83007.872005.9115011.83006.10155R8
0011.83007.872005.9115011.83007.87200R9
1)
Free space below is always measured from the drive frame, not from the cable box.
Free space, IP55 (UL Type 12)
1)
Frame
size
Horizontal mounting
Between
2)
Below
2)
,
3)
Above
2)
inmminmminmm
1.18/7.8730/2003.39865.91150R1
1.18/7.8730/2003.39865.91150R2
1.18/7.8730/2002.09537.87200R3
1.18/7.8730/2007.872001.1830R4
1.18/7.8730/2007.872001.1830R5
1)
Note: IP55/UL Type 12 drive mounted horizontally meets IP21/ UL Type 1 ratings.
2)
For definition, see the figure on page 64
3)
Free space below is always measured from the drive frame, not from the cable box.
Note: IP55 (UL Type 12) does not imply that the drive can be installed
outside/outdoors. To install outside, contact your local ABB representative directly
for specific instructions (3AXD10000425906). The warranty will be void if installed
outdoors without using these special instructions.
See the figures in section Installation alternatives (page 61).