364 Optional I/O extension modules
Isolation areas:
Analog inputs (80...82, 83...85)
Wire size max. 1.5 mm
2
Input voltage (AI+ and AI-): -10 V ... +10 V
Input resistance: > 200 kohm
Optional cable shield connection
Analog outputs (86...88, 89...91)
Wire size max. 1.5 mm
2
Output voltage (AO and AGND): 0 V ... 10 V
Output resistance: < 20 ohm
Recommended load: > 10 kohm
Inaccuracy: typical ± 1%, max. ± 1.5% of full scale
Optional cable shield connection
Analog output scale switch
ON state: 0.5 V ... 9.5 V range in use
OFF state: 0 V ... 10 V range in use
Symbol Description
1 Plugged to drive SLOT2
2 SWITCH
Reinforced insulation (IEC 61800-5-1:2007)
Functional insulation (IEC 61800-5-1:2007)
CBAI-01
1
AO3 AO4
AI4
AI4
2
Plugged to drive control unit SLOT21
Switch2
Reinforced insulation (IEC 61800-5-1:2007)
Functional insulation (IEC 61800-5-1:2007)
Dimension drawing
The dimensions are in millimeters and [inches].
1
A
B
C
D
E
F
2 3 4 5 6 7 8
A
B
C
D
E
F
Original drawing made with 3D CAD. Set the correct scale factor when adding dimensions after DWG/DXF conversion.First angle projection.
31 1.20[ ]
109 4.28[ ]
59 2.31[ ]
71 2.79[ ]
3AXD50000182008 -.2+
We reserve all rights in this document and in the information contained therein. Reproduction,
use or disclosure to third parties without express authority is strictly forbidden.
© ABB Oy. PROPRIETARY AND SECRET INFORMATION. CONFIDENTIAL
3AXD50000137442 (ASSEM) D.0+
Based on Prepared
A.Piirainen 04-Oct-17
Title
DIMENSION DRAWING
Doc. des. Scale Form
Customer Check.
P.Viitala 04-Oct-17 CBAI-01 DIMENSION DRAWING
DIMENSION DRAWING 1:1 A4
Appr.
J.Viman 04-Oct-17
Resp.dept. Rev.ind.
-.2 (DR)
Lang.
EN
Cust. Doc. No. Project name Doc. No.
3AXD50000182008
Sheet
1
DMS Number
3AXD10000653563
Weight kg
0.11
Total
1
A
Initial Approval 04-Oct-17 A.Piirainen
442 Optional I/O extension and adapter modules