North Americ-
an type
ACS580-01-
Frame sizeCommon mode filters
ABB drives
IEC type
ACS580-01-…
078A-4R564315811088A-4
096A-4R564315811106A-4
124A-4R63AXD50000017269145A-4
156A-4R73AXD50000017270169A-4
180A-4R73AXD50000017270206A-4
240A-4R83AXD50000018001246A-4
260A-4R83AXD50000018001293A-4
361A-4R93AXD50000017940363A-4
414A-4R93AXD50000017940430A-4
du/dt filters
■
When is a d
u
/d
t
filter needed?
See section Examining the compatibility of the motor and drive (page 96).
■
d
u
/d
t
filter types
IEC ratings at
U
n
= 230 V, UL (NEC) ratings at
U
n
= 208/230 V
North Americ-
an type
ACS580-01-…
d
u
/d
t
filters
ABB drives
Frame sizeIEC type
ACS580-01-…
04A6-2NOCH0016-6xR104A7-2
06A6-2NOCH0016-6xR106A7-2
07A5-2NOCH0016-6xR107A6-2
10A6-2NOCH0016-6xR1012A-2
017A-2NOCH0016-6xR1018A-2
024A-2NOCH0030-6xR2025A-2
031A-2NOCH0030-6xR2032A-2
046A-2NOCH0070-6xR3047A-2
059A-2NOCH0070-6xR3060A-2
075A-2NOCH0070-6xR4-
088A-2NOCH0070-6xR5089A-2
462 Common mode, d
u
/d
t
and sine filters