Parameters and firmware blocks
112
6.12 OP MODE ACK FW block: REFERENCE CTRL (page 183)
Operation mode acknowledge: 0 = Stopped, 1 = Speed, 2 = Torque, 3 = Min, 4 = Max, 5 = Add,
6 = Position, 7 = Synchron, 8 = Homing, 9 = Prof vel, 10 = Scalar, 11 = Forced magn (ie, DC Hold).
6.14 SUPERV STATUS FW block: SUPERVISION (page 178)
Supervision status word. See also parameter group 33 (page 178).
6.17 BIT INVERTED SW FW block: None
Shows the inverted values of the bits selected by parameters 33.17...33.22.
Bit Name Val. Information
0 SUPERV FUNC1
STATUS
1
Supervision function 1 is active (below low limit or over high
limit)
1 SUPERV FUNC2
STATUS
1
Supervision function 2 is active (below low limit or over high
limit)
2 SUPERV FUNC3
STATUS
1
Supervision function 3 is active (below low limit or over high
limit)
3…15 Reserved
Bit Name Information
0 INVERTED BIT0
See parameter 33.17 BIT0 INVERT SRC.
1 INVERTED BIT1
See parameter 33.18 BIT1 INVERT SRC.
2 INVERTED BIT2
See parameter 33.19 BIT2 INVERT SRC.
3 INVERTED BIT3
See parameter 33.20 BIT3 INVERT SRC.
4 INVERTED BIT4
See parameter 33.21 BIT4 INVERT SRC.
5 INVERTED BIT5
See parameter 33.22 BIT5 INVERT SRC.