Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
61.16 WindCtrlWord (winder control, winder control word, WCW)
The winder control word contains all winder depending commands and can be written to by AP or overriding control:
Name Value Comment
- 1 reserved
WriteToSpd 1 signals connected to the speed control chain are released
0 signals connected to the speed control chain are blocked
WindUnwind 1 rewinder
0 unwinder
-----------------------------------------------------------------------------------------------------
-------------------------------------------------------------
TopBottom 1 top (overwind)
0 bottom (underwind)
WinderOn 1 release winder
0 block winder
StartPID 1 release PID controller in group 40
0 block PID controller in group 40
SetDiameter 1 read DiameterValue (62.03) and connect it to DiameterAct (62.08)
0 calculate diameter and connect it to DiameterAct (62.08)
--------------------------------------------------------------------------------------------------------------------------
----------------------------------------
TensionOn 1 release tension
0 block tension
InerRelease 1 release inertia compensation
0 block inertia compensation
SetTension 1 release standstill tension reference
0 release tension reference
HoldTensRamp 1 hold tension ramp
0 release tension ramp
-----------------------------------------------------------------------------------------------------------------------------
-------------------------------------
TensionPulse 1 release tension pulse
0 no action
FrictRelease 1 release friction compensation
0 block friction compensation
Add1Release 1 release adder 1
0 block adder 1
Add2Release 1 release adder 2
0 block adder 2
Int. Scaling: 1 == 1 Type: I Volatile: Y
61.17 UsedWCW (winder control, used winder control word output, UWCW)
The used winder control word
is read only and contains all winder depending commands. The sources are selectable
depending on the parameter setting. The bit functionality is the same
as the in the WinderCtrlWord (61.16).
UsedWCW (61.17) is write protected, thus it is not possible to write on the used winder control word by AP or
Int. Scaling: 1 == 1 Type: I Volatile: Y
61.19 WindStatWord (winder control, winder status word, WSW)
The winder status word
is read only and contains the winder status bits.
Name Value Comment
- 1 reserved
WrittenToSpd 1 all winder block outputs are released and values of the connected ones are written to
WinderCtrlWord
(WCW)
61.16
Used WCW
(UWCW)
WindStatWord
(WSW)
to speed
control chain
to speed
control chain
61.17 61.19
Winder
logic
to speed
control chain
to speed
control chain
DCS550_Fw_blocksch_rev_a.dsf