11: CFM
7. Click Add to add a new MEP (Maintenance association End Point).
z MEP index: Unique index assigned to each Maintenance association End Point.
z MD index: Unique index assigned to each Maintenance Domain.
z MD name: The domain of the maintenance association (or MEG).
z MA/MAG index: The unique index of the maintenance association (or MEG).
z MA/MAG name: The maintenance association (or MEG).
z MEPID: Maintenance association End Point Identifier (MEPID). An integer, unique to each MA, identifying a
specific MEP in CCM frames.
z Port: Indicates the port used by this MEP.
z MAC address: Indicates the MAC address of the port used by this MEP.
z Direction: The direction in which the MEP faces on the Bridge port. This can be up or down.
z Active: Indicates the administrative state of the MEP. Checked indicates that the MEP is to function normally, and
Unchecked indicates that it is to cease functioning.
z CCI enable: Indicates, if set to true, that the MEP will generate CCM messages.