Installation
Follow this procedure to install the 35mm Bulk Load Camera Module
on the PCR II Plus film recorder:
Step 1: Remove the protective plastic cover from the lens in the
35mm bulk load camera module mounting plate assembly.
Caution:
Do not attempt to disassemble the mounting plate
assembly. This assembly has been adjusted and
aligned during manufacturing.
Step 2: Align the mounting plate inside the recessed area on top of
the PCR II Plus. The module fits tightly on the two registra-
tion pins and can only be oriented in one direction.
Step 3: Use the provided thumb-screws to secure the mounting plate
to the film recorder. Turn both screws clockwise until they
are tight.
Step 4: Make sure that the top of the mounting plate is clean and
dust free, then attach the film transport. Align the
1
/
4
inch
mounting pins on the mounting plate with the correspond-
ing holes in the bottom of the film transport. Make sure that
the transport is seated securely on the mounting plate.
Step 5: Use the provided 10-32 x
1
/
2
inch alien cap screws to attach
the film transport to the mounting plate.
Step 6: Plug the small male end of the module connector cable into
the top female connection at the back of the film transport.
Note: The bottom female connection at the back of
the film transport is not used with the PCR II Plus.
Step 7: Plug the right angle male end of the cable into the camera re-
ceptacle on the front panel of the PCR II Plus. Tighten the
connector by turning the outer ring clockwise.
2 • PCR II Plus 35mm Bulk Load Camera Module