Unloading the Film
Follow
this
procedure
to
unload
film:
Step 1: When you are ready to unload, press key A on the camera
module keypad. This advances the film 6 frames, which
moves the last exposed image from the camera body into the
take-up magazine.
Note: As a precaution, advance a few extra frames
into the take-up magazine to prevent exposing the
last image to light.
Step 2: Press the take-up magazine safety latch on the back of the
magazine. Lift the magazine and cut the film with a pair of
scissors.
Caution:
To help keep the exposed film from being exposed
to
light,
do not
lift
the
take-up
magazine
more
than
one inch from the camera body.
Step 3: Remove the exposed film from the take-up cassette. Use a
film changing bag or work in a darkroom.