Setting the Pacing Value
Step 1: Press MENU once then press PREVIOUS or NEXT repeatedly
until the message window displays SET PACING SELECT
FUNCTION.
Step 2: Press SELECT to enter the pacing submenu. The display
shows PACING HS SELECT VALUE or PACING nnn where
nnn is a number between three and 255. PACING HS has a
pacing value of zero.
Step 3: Press NEXT to increase the pacing number to a maximum of
255, PREVIOUS to lower the pacing number.
Step 4: Press SELECT to choose a pacing value and exit the pacing
submenu.
Step 5: Press MENU once to return to the Ready menu.
Guidelines for Selecting Pacing Values
The pacing values you select vary with the speed of the equipment
you use. With some rasterizers, you may need to use large pacing
values.
When imaging very complex graphics with photo drop-ins or large
amounts of text, you may obtain better results by using a pacing
value of seven to fifteen. This will have a minimal impact on the
total imaging time.
When using Mac Conductor, set the Pacing value in the FILM RE-
CORDER PREFERENCES dialog. Mac Conductor ignores the pac-
ing value set at the film recorder.
Image Control * 5-5